Accessibility Page Navigation
Style sheets must be enabled to view this page as it was intended.
Print Header
Border Top

S/FTP Cat 6 Marine Approved

Application: Data-Centres/SANs, Indoor use, fixed installations, High data rates, Maritime Environment, Optimized for IEEE 802.3at PoE+, Compliance with low voltage safety earth-connection and grounding regulations, Ships, High speed & Light craft
Conductor: Bare Copper

General construction: 4 individually foil-shielded twisted pairs, cabled together with a drain wire, overall braid-shielded and jacketed with a XL-HFFR compound. It exceeds IEC
61156-5 Cat. 6, and Cat. 5e transmission requirements.

Outer Jacket: SHF-1

Conductor Size: 23 AWG
Conductor Construction: Solid
Insulation Material: Cellular PO
Insulation O.D.: 1.35 mm nom.
Conductor unit identification: Solid Colour
Ind. Shield Material: Aluminium/Polyester Foil
Ind. Shield Design: Helically applied Aluminium foil, 100% coverage
Conductor unit lay-up: Pairs
Overall Shield Design: Braid
Overall Shield Material: Tinned-copper braid
Overall Braid Shield: Yes
Overall Braid Material: Tinned Copper
Braid Coverage: 55%nom.
Overall Drain-wire Material: Tinned Copper
Overall Drain-wire size: 0.41 mm
Overall Drain-wire Construction: Solid
Total number of conductors: 8
Outer Jacket Thickness: 0.8 mm nom.
Outer diameter: 8.0 mm nom.
Weight: 68 kg/km
Frequency Range: 1 - 400 MHz
Impedance: 100 Ω
Transfer Impedance: Grade 1
Coupling Attenuation: Type I
DC Resistance: 73 Ω/km nom.
Max. Resistance Unbalance: 2%
Max. Screen Resistance: 20 Ω/Km @20°C
Capacitance Unbalance: 1.2 pF/m max.
Velocity of Propagation: 78%nom.
Propagation Delay Skew: 25 ns/100m max.
Dielectric Strength: 700 V/minute
Dielectric Strength to Shield: 700 V/minute
Min. Insulation Resistance : 5 GΩ•km
Tensile Strength - Short Term: 130 N max.
Min. Bend Radius: 60 mm
Max. Operating Temperature: + 85 °C
Min. Operating Temperature: - 40 °C
Applicable Standards:
DNV - TYPE DB Non-Armoured Solid Copper Conductor Cable, IEC 60092-359, IEC1156, IEEE 802.3at (PoE+), ISO/IEC 11801, RoHS-2 2011/65/EU
Flammability Rating: IEC 60332-1, IEC 60332-3-24, IEC 60754-2, IEC 61034-1/2

Technical Information

Batt Part No. Core Size Colour/Reference Quote
91592 Get Quote
Related Products