Applications: Rigid wire red copper conductor class 1 (section <= 4 mm2)
Stranded circular compacted copper conductors class 2 (secetion
>4mm2)
XLPE Crosslinked polyethylene insulation(no dry cool).
Special Outer sheath PVC.
For use on industrial sites and the upright columns of buildings. Particularly suited in cases of high operating temperatures and when high resistance to solar radiation and atmospheric agents is required. Good resistance to low temperatures, chemical agents and UV .It can be used without additional mechanical protection in the open air, fixed to walls or in raceways, inside walkways, and in empty in constructions in general. It can be laid undrground with mechanical protection constucted from slabs, tiles, or bricks. It is not racommend to lay thiscable in ground flooded for more than two months per year. With appropriate mechanical protection it can be use in areas subject to risk of explosion, but in this case the permitted current load is reduced by 15%
Core Colours: Single core: Black Two cores: blue-brown
Three cores: brown-black-blue (1,5/2,5mmq); brown-black-gray (4mmq) or Y/G-blue-brown)
Four cores: blue-brown-black-gray (or Y/G instead blue)
Five cores: blue-brown-black-gray-Y/G (or black instead Y/G)
Colour: Singlecore cables and multicore cables (over 5 cores) with black sheath. From 2 up to 5 cores, black sheath with colored strip.
Bending radius: Minimum bending radius per D cable diameter (in mm):
6D
Maximum pulling stress:
5kg/mm² (of copper cross section)
L/R ratio: Nominal voltage U0: 600 V
Nominal voltage : 1000 V
Test voltage: 4000 V
Maximun voltage Um: 1200 V
Maximun operating temperature: +90°C
Maximun short circuit temperature: +250°C
Min. operating temperature (without mechanical shocks): -25°C
Minimum installation and use temperature: -10°C
Standards: NF XP C32-321 IEC60502-1 NF EN 60332-1-2 Category C2 NF C 15-100
Whilst BATT CABLES plc endeavours to ensure the information on the website, specification sheets and all other technical information is accurate, the information is for guidance only and it is subject to change without notice or liability. Batt Cables Plc is not responsible for the consequences of any inadequacies, inaccuracies or other deficiencies contained therein. When selecting cable accessories, please note that the actual cable dimensions may vary due to manufacturing tolerances.
Batt Part No. | Core | Size | Colour/Reference | Quote |
---|---|---|---|---|
29000 | 1 | 16 | Get Quote | |
16936 | 1 | 95sqmm | Get Quote | |
16938 | 1 | 120sqmm | Get Quote | |
16937 | 1 | 185sqmm | Get Quote | |
16935 | 1 | 240sqmm | Get Quote | |
29003 | 2 | 1.5sqmm | Get Quote | |
29001 | 2 | 2.5sqmm | Get Quote | |
29026 | 2 | 6sqmm | Get Quote | |
29004 | 2 | 10sqmm | Get Quote | |
29005 | 2 | 16sqmm | Get Quote | |
29006 | 2 | 25sqmm | Get Quote | |
29002 | 3 | 1.5sqmm | Get Quote | |
29007 | 3G | 1.5 | Get Quote | |
29008 | 3G | 2.5 | Get Quote | |
29009 | 3G | 4sqmm | Get Quote | |
29010 | 3G | 6sqmm | Get Quote | |
16877 | 4 | 25sqmm | Get Quote | |
29011 | 4G | 1.5sqmm | Get Quote | |
29012 | 4G | 2.5sqmm | Get Quote | |
29013 | 4G | 4sqmm | Get Quote | |
29014 | 4G | 6sqmm | Get Quote | |
29015 | 4G | 10sqmm | Get Quote | |
16876 | 4 | 10sqmm | Get Quote | |
16866 | 4 | 16sqmm | Get Quote | |
29016 | 4G | 25sqmm | Get Quote | |
29017 | 5G | 1.5sqmm | Get Quote | |
29018 | 5G | 2.5sqmm | Get Quote | |
29019 | 5G | 4sqmm | Get Quote | |
16895 | 5G | 10sqmm | Get Quote | |
29025 | 5G | 6sqmm | Get Quote | |
16893 | 5G | 16sqmm | Get Quote | |
29020 | 5G | 25sqmm | Get Quote | |
29021 | 5G | 35sqmm | Get Quote | |
29022 | 7G | 1.5sqmm | Get Quote | |
29023 | 12 | 1.5sqmm | Get Quote | |
29024 | 19G | 1.5sqmm | Get Quote |