Accessibility Page Navigation
Style sheets must be enabled to view this page as it was intended.
Print Header
Border Top

U-1000 R02V

Applications: Rigid wire red copper conductor class 1 (section <= 4 mm2)
Stranded circular compacted copper conductors class 2 (secetion
>4mm2)
XLPE Crosslinked polyethylene insulation(no dry cool).
Special Outer sheath PVC.
For use on industrial sites and the upright columns of buildings. Particularly suited in cases of high operating temperatures and when high resistance to solar radiation and atmospheric agents is required. Good resistance to low temperatures, chemical agents and UV .It can be used without additional mechanical protection in the open air, fixed to walls or in raceways, inside walkways, and in empty in constructions in general. It can be laid undrground with mechanical protection constucted from slabs, tiles, or bricks. It is not racommend to lay thiscable in ground flooded for more than two months per year. With appropriate mechanical protection it can be use in areas subject to risk of explosion, but in this case the permitted current load is reduced by 15%
Core Colours: Single core: Black Two cores: blue-brown
Three cores: brown-black-blue (1,5/2,5mmq); brown-black-gray (4mmq) or Y/G-blue-brown)
Four cores: blue-brown-black-gray (or Y/G instead blue)
Five cores: blue-brown-black-gray-Y/G (or black instead Y/G)
Colour: Singlecore cables and multicore cables (over 5 cores) with black sheath. From 2 up to 5 cores, black sheath with colored strip.
Bending radius: Minimum bending radius per D cable diameter (in mm):
6D
Maximum pulling stress:
5kg/mm² (of copper cross section)
L/R ratio: Nominal voltage U0: 600 V
Nominal voltage : 1000 V
Test voltage: 4000 V
Maximun voltage Um: 1200 V
Maximun operating temperature: +90°C
Maximun short circuit temperature: +250°C
Min. operating temperature (without mechanical shocks): -25°C
Minimum installation and use temperature: -10°C
Standards: NF XP C32-321 IEC60502-1 NF EN 60332-1-2 Category C2 NF C 15-100

Whilst BATT CABLES plc endeavours to ensure the information on the website, specification sheets and all other technical information is accurate, the information is for guidance only and it is subject to change without notice or liability. Batt Cables Plc is not responsible for the consequences of any inadequacies, inaccuracies or other deficiencies contained therein. When selecting cable accessories, please note that the actual cable dimensions may vary due to manufacturing tolerances.  

Technical Information

Specification

Batt Part No. Core Size Colour/Reference Quote
29000 1 16 Get Quote
16936 1 95sqmm Get Quote
16938 1 120sqmm Get Quote
16937 1 185sqmm Get Quote
16935 1 240sqmm Get Quote
29003 2 1.5sqmm Get Quote
29001 2 2.5sqmm Get Quote
29026 2 6sqmm Get Quote
29004 2 10sqmm Get Quote
29005 2 16sqmm Get Quote
29006 2 25sqmm Get Quote
29002 3 1.5sqmm Get Quote
29007 3G 1.5 Get Quote
29008 3G 2.5 Get Quote
29009 3G 4sqmm Get Quote
29010 3G 6sqmm Get Quote
16877 4 25sqmm Get Quote
29011 4G 1.5sqmm Get Quote
29012 4G 2.5sqmm Get Quote
29013 4G 4sqmm Get Quote
29014 4G 6sqmm Get Quote
29015 4G 10sqmm Get Quote
16876 4 10sqmm Get Quote
16866 4 16sqmm Get Quote
29016 4G 25sqmm Get Quote
29017 5G 1.5sqmm Get Quote
29018 5G 2.5sqmm Get Quote
29019 5G 4sqmm Get Quote
16895 5G 10sqmm Get Quote
29025 5G 6sqmm Get Quote
16893 5G 16sqmm Get Quote
29020 5G 25sqmm Get Quote
29021 5G 35sqmm Get Quote
29022 7G 1.5sqmm Get Quote
29023 12 1.5sqmm Get Quote
29024 19G 1.5sqmm Get Quote
Related Products