BS5308 PVC instrumentation cable - Part 2 Type 1 CAM PVC
BATT Part number: 85069
Applications: Generally used within industrial process plants and for data & voice transmission services. Also used for the interconnection of electrical equipment and instruments, particularly in and around process plants, where transducer generated signals are transmitted through marshalled circuits to panels, controllers and associated devices . Part 2 cables are common to the chemical and petrochemical industries. Type 1 unarmoured cables are generally for indoor applications
Conductors: 3 x 0.75mm² class 5 Flexible copper
Composition: 24 x 0.20mm
Cores: IEC 60228 Copper
Diameter: 5.00mm
Colour: Black
Voltage: 500v
Overall diameter: 6.90mm Dimensional tolerance -0 + 7%
Insulation: PVC
Thickness: 0.60 mm
Core Identification: BS5308 Part 2 twisted
Overall shield: Aluminium/polyester tape of 0.05mm thickness with stranded tinned copper drain wire
Screen: CAM
Sheath/Jacket: PVC
Resistance: 26.000 Ohm/km max
Capacitance: 0.180 µF/km
Inductance: 0.900 mH/km
Standards: BS5308 Part 2, insulated cables, instrumentation, PVC, Flame retardant to IEC 60332-3-24