Accessibility Page Navigation
Style sheets must be enabled to view this page as it was intended.
Print Header
Border Top

XI 331 Cable Unarmoured 600/1000V

XI 331 Cable Unarmoured 600/1000V

XI 331 fire resistant power cable to IEC60092-353 and IEC60331 

Conductor: plain flexible compacted copper IEC60228 Class 2

Insulation: mica tape plus XLPE compound insulated

Bedding: halogen free FLAMEBAR ® bedding

Sheath: halogen free LSZH sheath

Design and Construction: IEC60092-353
Nominal Voltage Uo/U: 0,6/1 kV
Maximum Votage Umax: 1,2 kV
Flame Retardancy: IEC 60332-1 IEC 60332-3 Cat A
Fire Resistancy: IEC 60331
Corrosivity: IEC 60754-1 IEC 60754-2
Smoke Density: IEC 61034-2
Toxicity and Smoke Density: IMO RESOLUTION MSC 41(64) and ATS 1000.001 tech. spec.
Cold bend and impact test (-40oC) CSA C22.2 No 38-95
Cores Identification: 1 core black, 2 core black & light blue
3 core black, brown & light blue, 4 core black, blue, brown & white, 5 core white and numbered
Earthing core (on request) green/yellow
Sheath Colour: Black

Ref: XI 331cable

Operating temperature: Maximum 100°C, minimium bending -40°C

Standard: IEC60092-353: power cables for electrical installation in ships

Type approvals: ABS, Bureau Veritas, DNV, Lloyd’s Register & Russian Maritime Register of Shipping

ABS BV DNV lloyds RM

Applications: Marine applications where circuit integrity is important in the event of a fire, including shipwiring

Specification

Batt Part No. Core Size Colour/Reference Quote
14162 2 1.5sqmm Black Get Quote
14130 2 2.5sqmm Black Get Quote
14116 3 1.5sqmm Black Get Quote
14115 3 2.5sqmm Black Get Quote
14186 3 16sqmm Black Get Quote
14289 3 35sqmm Black Get Quote
14188 3 95sqmm Black Get Quote
14189 4 1.5sqmm Black Get Quote
14114 4 2.5sqmm Black Get Quote
14118 7 1.5sqmm Black Get Quote
14288 12 1.5sqmm Black Get Quote
14117 19 1.5 Black Get Quote