BATT Part No: 20003
Application: Signal cable type C to Network Rail Signalling Cable. Type C3
Conductor: Tinned annealed flexible copper. Class 5 to BS6360
Insulation: EPR (Ethylene propylene rubber) with type G4 properties
Core identification: Black, red & green/yellow or black and numbered
Screen: CAM (collective aluminium mylar)
Sheath: HDPCP (Heavy duty polychloroprene) RS2
Sheath colour: Black
Operating temperature: Maximum 80°C, Minimum bending -30°C
No of cores: 2
Conductor size: 2.5mm²
Nom diameter of conductor: 2.00mm
Max diameter of conductor: 2.30mm
Thickness of insulation: As required to meet characteristics impedance
Min core diameter: 3.90 mm
Nom core diameter: 4.90 (specified only due to characteristic impedance)
Thickness of sheath: 3.80mm
Min cable diameter: 15.00 mm
Max cable diameter: 18.80 mm
Nominal weight of cable: 339 kg/km
Max dc resistance of conductors at 20°C: 8.21W/km
Min insulation resistance at 500 Vdx and 20°C: 650 MW/km
Characteristic impedance at 65kHz: 70 to 80 W
Mutual capacitance at 65KHz: 95 ± 10 nF/km
Max cores to screen capacitance at 65kHz: 420 nF/km
Attenuation at 65kHz: 0.5dB/100m
Max pulling force for drawing cable: 245 N
Voltage: 650/1100v
Network Rail catalogue number: 6/160086
Standards: Network Rail Signal Cable to NR/E/PS/0005, BS6360
Whilst BATT CABLES plc endeavours to ensure the information on the website, specification sheets and all other technical information is accurate, the information is for guidance only and it is subject to change without notice or liability. Batt Cables Plc is not responsible for the consequences of any inadequacies, inaccuracies or other deficiencies contained therein. When selecting cable accessories, please note that the actual cable dimensions may vary due to manufacturing tolerances.
Batt Part No. | Core | Size | Colour/Reference | Quote |
---|---|---|---|---|
20003 | 3 | 2.5sqmm (Class 5) | Black | Get Quote |