BS6724 AWA LSZH Cable IEC 60502 600/1000V

BS6724 AWA LSZH Cable IEC 60502 600/1000V
Applications: Power cable suitable for power networks and direct burial, where fire and emissions of smoke and toxic fumes create a serious potential threat. Armoured LSZH power cable to British Standard BS6724 & IEC 60502 suitable for mains power networks

Conductors: Plain annealed stranded copper

Conductor stranding: Class 2 - stranded circular or circular compacted

Insulation: XLPE (Cross linked polyethylene)

Core identification: Brown

Bedding: LSZH (Low smoke zero halogen)

Armour/Protection: AWA (Aluminium wire armour) non-magnetic

Sheath/Jacket: LSZH (Low smoke zero halogen)

Colour: Black

Voltage: 600/1000v

Operating temperature Maximum 90°C

Conductor identification: Brown

Minimum bending radius: 6 x Overall diameter (wherever possible, larger installation radi should be used)

Combustion characteristics: Oxygen index: 35 (Temperature index 280°C)
HCL emission 0.5% in accordance with BSEN50267-1 common test methods for cables under fire conditions. Tests on gases evolved during combustion of materials from cables. Procedures, determination of the amount of halogen acid gas.

Standard: BS6724: Electric cables. Thermosetting insulated, armoured cables for voltages of 600/1000V and 1900/3300V, having low emission of smoke and corrosive gases when affected by fire BSEN50267-1 Common test methods for cables under fire conditions. Tests on gases evolved during combustion of materials from cables. Apparatus BSEN50267-2-1:Common test methods for cables under fire conditions. Tests on gases evolved during combustion of materials from cables. Procedures. Determination of the amount of halogen acid gas BSEN50266-1 Common test methods for cables under fire conditions. Test for vertical flame spread of vertically-mounted bunched wires or cables
IEC 60502: Power cables with extruded insulation and their accessories for rated voltages from 1kV to 30kV
BSEN/IEC60332-1-2: Tests on electric and optical fibre cables under fire conditions Part 1: test for vertical flame propagation for a single insulated wire or cable Section 2: procedure for 1kW pre-mixed flame
BSEN61034-2:2005 Measurement of smoke density of cables burned under defined conditions. Test procedure and requirements
Flame Propagation Test to BS EN 60332-1-2:2004 for single cable and BS EN 60332-3-24:2009 (Cat C) for multiple cables

Notes: For current rating refer to Table 4E3A. If you are considering installing in high UV exposure and/or high/low ambient temperatures i.e. desert/arctic conditions then special sheathing may be required

Batt Part No. Core Size Colour/Reference Quote
56415 1 50sqmm Black Get Quote
56416 1 70sqmm (Class 2) Black Get Quote
56417 1 95sqmm (Class 2) Black Get Quote
56418 1 120sqmm (Class 2) Black Get Quote
56419 1 150sqmm (Class 2) Black Get Quote
56420 1 185sqmm (Class 2) Black Get Quote
56421 1 240sqmm (Class 2) Black Get Quote
56422 1 300sqmm (Class 2) Black Get Quote
56423 1 400sqmm (Class 2) Black Get Quote
56424 1 500sqmm (Class 2) Black Get Quote
56425 1 630sqmm (Class 2) Black Get Quote
56426 1 800sqmm (Class 2) Black Get Quote
56427 1 1000sqmm (Class 2) Black Get Quote