RS232/RS423 Dual Shielded Cable 9934, 9936

RS232/RS423 Dual Shielded Cable 9934, 9936

RS232/RS423 Dual Shielded Cable 9934, 9936

Conductor: 24 awg (7/32 awg - 0.2mm) stranded tinned annealed copper 

Insulation: Cellular-polypropylene

Screen: Collective aluminium-polyester shield inc 24 awg stranded tinned copper drain wire under tinned copper braid shield

Sheath: PVC grey jacket 30V 80 degrees C

Applications: High speed data, extended distance, low capacitance, suitable for EIA RS232 & RS423 CAD/CAM

9936

Whilst BATT CABLES plc endeavours to ensure the information on the website, specification sheets and all other technical information is accurate, the information is for guidance only and it is subject to change without notice or liability. Batt Cables Plc is not responsible for the consequences of any inadequacies, inaccuracies or other deficiencies contained therein. When selecting cable accessories, please note that the actual cable dimensions may vary due to manufacturing tolerances.  

Technical Information

Batt Part No. Core Size Colour/Reference Quote
91120 9 7/32 awg - 0.2mm Grey ref 9934 Get Quote
91243 15 7/32 awg - 0.2mm Grey ref 9936 Get Quote