Fire performance power cable to BS6837 suitable as fire alarm cable and emergency lighting cable
Conductor: Plain annealed stranded copper to BSEN60228 (class 2)
Fire barrier: MGT (Mica glass tape)
Insulation: XLPE (Cross linked polyethylene)
Core identification: 2 core:Brown & blue, 3 core: Brown, black & grey, 4 core: Brown, grey, blue & black, Multicore: White cores with black numerals
Bedding: LSZH (Low smoke zero halogen)
Armour/Protection: SWA (Single wire armour)
Sheath/Jacket: LSZH (Low smoke zero halogen)
Colour: Black
Voltage: 600/1000v
Operating temperature: Maximum 90°C, minimum bending: -0°C, minimum operating: -10°C
Standards: BS6387, Categories C, W & Z, Specification for performance requirements for cables required to maintain circuit integrity under fire conditions
IEC60331: Tests for electric cables under fire conditions - circuit integrity
BS EN 61034:2005: Measurement of smoke density of cables burned under defined conditions. Test procedure and requirements
BS6724: Electric cables. Thermosetting insulated, armoured cables for voltages of 600/1000V and 1900/3300V, having low emission of smoke and corrosive gases when affected by fire
BS7846: Electric cables. 600/1000 V armoured fire-resistant cables having thermosetting insulation and low emission of smoke and corrosive gases when affected by fire
BS EN 50266:2001: Common test methods for cables under fire conditions. Test for vertical flame spread of vertically-mounted bunched wires or cables
Fire Resistance BS6387 Categories C, W & Z:
IEC60331: 750 deg C for 3 hours
Flame Propagation BS EN 50266 parts 1 and 3, IEC 60332-3, BS EN 60332:2004
Smoke Emission IEC 61034, BS EN 61034:2005
Corrosive Acid Gas BS EN 50267-2-1:1999, IEC 60754-1
Fire resistant to IEC 60331 1-2
Applications: Fire performance cables maintain circuit integrity in a fire and so are suitable for fire detection, alarm and emergency lighting systems
Minimum Bending Radius: 6 x Overall Diameter for Circular Conductors. 8 x Overall Diameter for Shaped Conductors
Whilst BATT CABLES plc endeavours to ensure the information on the website, specification sheets and all other technical information is accurate, the information is for guidance only and it is subject to change without notice or liability. Batt Cables Plc is not responsible for the consequences of any inadequacies, inaccuracies or other deficiencies contained therein. When selecting cable accessories, please note that the actual cable dimensions may vary due to manufacturing tolerances.
Batt Part No. | Core | Size | Colour/Reference | Quote |
---|---|---|---|---|
57183 | 2 | 1.5sqmm (Class 2) | Black | Get Quote |
57184 | 2 | 2.5sqmm (Class 2) | Black | Get Quote |
57185 | 2 | 4.0sqmm (Class 2) | Black | Get Quote |
57186 | 2 | 6.0sqmm (Class 2) | Black | Get Quote |
57187 | 2 | 10sqmm (Class 2) | Black | Get Quote |
57188 | 2 | 16sqmm (Class 2) | Black | Get Quote |
57189 | 2 | 25sqmm (Class 2) | Black | Get Quote |
57190 | 2 | 35sqmm (Class 2) | Black | Get Quote |
57191 | 2 | 50sqmm (Class 2) | Black | Get Quote |
57192 | 2 | 70sqmm (Class 2) | Black | Get Quote |
57193 | 2 | 95sqmm (Class 2) | Black | Get Quote |
57194 | 2 | 120sqmm (Class 2) | Black | Get Quote |
57195 | 2 | 150sqmm (Class 2) | Black | Get Quote |
57196 | 2 | 185sqmm (Class 2) | Black | Get Quote |
57197 | 2 | 240sqmm (Class 2) | Black | Get Quote |
57198 | 2 | 300sqmm (Class 2) | Black | Get Quote |
57199 | 2 | 400sqmm (Class 2) | Black | Get Quote |
57212 | 3 | 1.5sqmm (Class 2) | Black | Get Quote |
57213 | 3 | 2.5sqmm (Class 2) | Black | Get Quote |
57214 | 3 | 4.0sqmm (Class 2) | Black | Get Quote |
57215 | 3 | 6.0sqmm (Class 2) | Black | Get Quote |
57216 | 3 | 10sqmm (Class 2) | Black | Get Quote |
57217 | 3 | 16sqmm (Class 2) | Black | Get Quote |
57218 | 3 | 25sqmm (Class 2) | Black | Get Quote |
57219 | 3 | 35sqmm (Class 2) | Black | Get Quote |
57220 | 3 | 50sqmm (Class 2) | Black | Get Quote |
57221 | 3 | 70sqmm (Class 2) | Black | Get Quote |
57222 | 3 | 95sqmm (Class 2) | Black | Get Quote |
57223 | 3 | 120sqmm (Class 2) | Black | Get Quote |
57224 | 3 | 150sqmm (Class 2) | Black | Get Quote |
57225 | 3 | 185sqmm (Class 2) | Black | Get Quote |
57226 | 3 | 240sqmm (Class 2) | Black | Get Quote |
57227 | 3 | 300sqmm (Class 2) | Black | Get Quote |
57228 | 3 | 400sqmm (Class 2) | Black | Get Quote |
57200 | 4 | 1.5sqmm (Class 2) | Black | Get Quote |
57201 | 4 | 2.5sqmm (Class 2) | Black | Get Quote |
57202 | 4 | 4.0sqmm (Class 2) | Black | Get Quote |
57203 | 4 | 6.0sqmm (Class 2) | Black | Get Quote |
57204 | 4 | 10sqmm (Class 2) | Black | Get Quote |
57205 | 4 | 16sqmm (Class 2) | Black | Get Quote |
57236 | 4 | 25sqmm (Class 2) | Black | Get Quote |
57230 | 4 | 35sqmm (Class 2) | Black | Get Quote |
57237 | 4 | 50sqmm (Class 2) | Black | Get Quote |
57243 | 4 | 70sqmm (Class 2) | Black | Get Quote |
57231 | 4 | 95sqmm (Class 2) | Black | Get Quote |
57232 | 4 | 120sqmm (Class 2) | Black | Get Quote |
57233 | 4 | 150sqmm (Class 2) | Black | Get Quote |
57234 | 4 | 185sqmm (Class 2) | Black | Get Quote |
57254 | 4 | 240sqmm (Class 2) | Black | Get Quote |
57235 | 4 | 300sqmm (Class 2) | Black | Get Quote |
57253 | 4 | 400sqmm (Class 2) | Black | Get Quote |
57247 | 5 | 1.5sqmm (Class 2) | Black | Get Quote |
57248 | 5 | 2.5sqmm (Class 2) | Black | Get Quote |
57130 | 7 | 1.5sqmm (Class 2) | Black | Get Quote |
57142 | 7 | 2.5sqmm (Class 2) | Black | Get Quote |
57106 | 12 | 1.5sqmm (Class 2) | Black | Get Quote |
57143 | 12 | 2.5sqmm (Class 2) | Black | Get Quote |
57145 | 19 | 1.5sqmm (Class 2) | Black | Get Quote |
57144 | 19 | 2.5sqmm (Class 2) | Black | Get Quote |
57239 | 27 | 2.5sqmm (Class 2) | Black | Get Quote |
57125 | 37 | 1.5sqmm (Class 2) | Black | Get Quote |
57060 | 37 | 2.5sqmm (Class 2) | Black | Get Quote |
57113 | 48 | 2.5sqmm | Black | Get Quote |
57247 | 5 | 1.5 | Get Quote | |
57248 | 5 | 2.5 | Get Quote | |
57249 | 5 | 4 | Get Quote | |
57250 | 5 | 6 | Get Quote | |
57331 | 5 | 10 | Get Quote | |
57329 | 5 | 16 | Get Quote | |
57330 | 5 | 25 | Get Quote |