Fire & Security

BATT CABLES plc offers many fire cables which are suitable for critical safety systems including emergency power supplies & lighting, fire alarms, sprinkler systems, CCTV, security alarms and PA systems. Fire cables have a low smoke, zero halogen sheath (LSZH) and so are suitable for installation in public buildings where improved visibility for evacuation and a reduction in toxic fumes are important. All our fire cables comply with the relevant national and international standards including BS6387, BS7629, IEC 60331 and IEC 60332.
A range of mineral cables are also available which will continue to operate even after exposure to fire.

• Alarm installers
• Electrical contractors
• Security companies


Cables

 Unarmoured fire cable   Security cable
 Armoured fire cable  Mineral cable
 CW1600 fire resistant telephone cable  Emergency Lighting Cable
 Fire Alarm Cable  

Approvals
BATT CABLES plc are cable suppliers who stock many cables certified by the LPCB - Loss Prevention Certification Board who are dedicated to approving fire products worldwide

Standards
All cables supplied comply with British, European and International specifications including:
BS5266-1:2005 Emergency lighting. Code of practice for the emergency lighting of premises
BS5839-8:2008 Fire detection and fire alarm systems for buildings. Code of practice for the design, installation, commissioning and maintenance of voice alarm systems
BS6387:1994 Specification for performance requirements for cables required to maintain circuit integrity
BS7629-1:2008 Electric Cables. Specification for 300/500V fire resistant screened cables having low emission of smoke and corrosive gases when affected by fire. Mulitcore and multipair cables
BS7846:2000 Electric Cables. 600/1000V armoured fire-resistant cables having thermosetting insulation and low emission of smoke and corrosive gases when affected by fire
BSEN 50266-1:2001 Common test methods for cables under fire conditions. Test for vertical flame spread of vertically-mounted bunched wires or cables
BSEN 50267-1:1999 Common test methods for cables under fire conditions. Tests on gases evolved during combustion of materials from cables. Apparatus
BSEN 50267-2-1:1999 Common test methods for cables under fire conditions. Tests on gases evolved during combustion of materials from cables. Procedures. Determination of the amount of halogen acid gas
BSEN 50267-2-2:1999 Common test methods for cables under fire conditions. Tests on gases evolved during combustion of materials from cables. Procedures. Determination of degree of acidity of gases for materials by measuring pH and conductivity
BSEN 50267-2-3:1999 Common test methods for cables under fire conditions. Tests on gases evolved during combustion of materials from cables. Procedures. Determination of degree of acidity of gases for cables by determination of the weighted average of pH and conductivity
BSEN 61034-2:2005 Measurement of smoke density of cables burned under defined conditions. Test procedure and requirements
BSEN60702:2002 Mineral insulated cables and their terminations with a rated voltage not exceeding 750V
IEC 60331 Tests for electric cables under fire conditions - circuit integrity
IEC60332 Tests on electric and optical fibre cables under fire conditions
IEC60702:2002 Mineral insulated cables and their terminations with a rated voltage not exceeding 750V

Service
BATT CABLES plc is dedicated to providing an effective one-stop source for both project and day-to-day cable demands. With ISO9001 accreditation at all branches, quality of service is assured. The company has an extensive stockholding of cables and can offer a project cable management service including cutting cables to length, labeling and a full documentation facility.

 